Ceph Tracing — cephalometric analysis of a lateral ceph

What it is forTrace a lateral cephalogram: place the landmarks, calibrate with the ruler, and get Steiner, Downs, Tweed, McNamara, Wits, Kim, Björk, Tweed–Merrifield, Jarabak, Ricketts, COGS, Arnett and soft-tissue values at once, each with its inference, plus a problem list. Send the traced picture and all values to the patient document, compare pre-, mid- and post-treatment tracings with Ricketts' superimposition (four areas, their composite and the esthetic plane), and trace a PA ceph for Grummons' frontal asymmetry analysis.
What you getA saved tracing on the patient, a PDF report, and (when you send it) a "Cephalometric analysis" section in the full patient document.
Where to find itLeft menu → Ceph Tracing
Who can use itOwner and staff with the Imaging (RVG) permission

Good to know: Included from the Medium plan. Also sold on its own as the Ceph Tracing plan (1, 2 or 3–4 users; each login works on one device at a time), which opens only this tool and has its own login page (/ceph-tracing/login).

1Start a tracing

  1. Click Ceph Tracing in the left menu. (From a patient page you can also click Ceph tracing in the X-rays box.)
  2. Search and choose the patient. New patient? Click New patient at the top of the search list, type the name (mobile is optional) and click Save patient.
  3. Click Upload X-ray and choose the lateral ceph file (JPG, PNG, TIFF or DICOM). Or click From Imaging to use a ceph already in Imaging (RVG).
  4. The tracing screen opens by itself.

Tip: Use the full-size file from the X-ray machine. A photo of the screen or a small WhatsApp copy makes points harder to place.

Note: DICOM files that carry the pixel size are calibrated automatically. From Imaging is shown only when your plan includes X-ray imaging.

Drawing of the screen. Your own names and numbers will be different.

2Patients and the patient document (Ceph Tracing plan)

  1. Click Patients in the left menu.
  2. Click Add patient, fill in the name (mobile, email, gender, date of birth and address are optional) and click Save patient.
  3. Click the patient, then New / open ceph tracing to work on them.
  4. In the tracing, click Send to document. The report is saved in that patient's document.
  5. Back in Patients, click the patient: every report you sent is listed. Click Report for one report, or Download patient document (PDF) for all of them with a cover page of the patient's details.

Tip: The patient document holds only the reports you sent with Send to document. Click the × next to a report to take it out of the document — the analysis itself is kept.

Drawing of the screen. Your own names and numbers will be different.

3Calibrate (for mm values)

  1. Click Calibrate in the top bar.
  2. Zoom in on the ruler of the cephalostat. Click one mark, then a second mark a known distance away (for example 10 mm apart).
  3. Type the real length in Real length and click Save.
  4. Only if your machine needs it, enter its Magnification correction in %.

Tip: Without calibration, angles still work. Values in mm (Wits, McNamara, lips to E-line and others) stay empty, so a wrong number is never shown.

Drawing of the screen. Your own names and numbers will be different.

4Place the points

  1. Click Place in the top bar. The panel on the left shows the Next point with a short tip where it goes.
  2. Click on the X-ray where the point is. A magnifier follows the mouse so you can be exact.
  3. The next point is chosen by itself. Click any name in the list to place or redo that point.
  4. Scroll to zoom. Hold Shift and drag (or use the hand) to move the X-ray.
  5. To fix a point, click Move, drag it, or use the arrow keys (Shift + arrow moves 5 pixels). Delete removes it and Ctrl+Z undoes.

Tip: Use Brightness, Contrast and Invert in the top bar to see soft tissue and the sella clearly.

Drawing of the screen. Your own names and numbers will be different.

5Use suggested points to go faster

  1. Place at least two points yourself (S and N are best; more points give better suggestions).
  2. Click Suggest points. Dotted circles show where the other points probably are.
  3. Drag a dotted circle onto the real structure, or press Enter to accept the suggestion for the next point.
  4. Or click Add all as estimated: they turn orange. Click or drag each orange point after checking it, and it turns green.
  5. Orange points are left out of the results unless you tick Include estimated points.

Note: Suggestions come from an average face fitted to your points. They are not automatic detection and are often a few mm off. Always check each one on the X-ray.

Drawing of the screen. Your own names and numbers will be different.

6Read the results

  1. The right panel has two tabs. Problem list & diagnosis shows the findings grouped as Skeletal, Dental and Soft tissue (for example "Skeletal Class II (moderate)", "Lower incisor inclination: Proclined"), each with the values it is based on.
  2. Above the list, choose Norms for Female or Male (COGS and Arnett have separate norms) and, if you have checked the models, the Molar relationship. Otherwise it is estimated from the X-ray.
  3. Type your own Clinician's diagnosis and Treatment plan below the list. Both are printed in the PDF report.
  4. Open All measurements to see every analysis: Orientation & cranial base (SN-FH angle and how much the head is tipped on the X-ray), Steiner, Downs, Tweed, McNamara, Wits, Kim (APDI / ODI), Incisors & occlusion, Björk, Tweed–Merrifield, Jarabak, Ricketts, COGS, Arnett, Vertical soft tissue proportions, Soft tissue and the Composite analysis (seven parts: maxilla, mandible, sagittal and vertical jaw relation, dentoalveolar, soft tissue and airway — with the Beta, Yen and W angles). The Beta angle needs the C point (condyle centre); the Yen and W angles need the M point (centre of the premaxilla) and the G point (centre of the symphysis). A few values (for example Pr-N-SS) have no published norm; they are shown for comparing before and after treatment. Ricketts values that change with growth (molar position, cranial length, corpus length, mandibular arc and others) use the norm for the patient's age on the X-ray date, and McNamara's Co-A, Co-Gn, maxillo-mandibular difference and lower anterior face height use the Bolton standards for the patient's age (6 to 18 years) and sex, so add the date of birth and choose the sex under Norms for. Xi is built from the four ramus points R1–R4, and the airway values need the four Airway points.
  5. Each line shows the value, the norm (mean ± SD) and its inference, for example "Protruded maxilla". Stars show how far from the mean: one star 1–2 SD, two stars 2–3 SD, three stars more than 3 SD.
  6. A line that says Needs … tells which points are still missing.

Note: The inference and problem list are worked out from population norms and the points you placed. They are an aid; confirm every finding clinically.

Drawing of the screen. Your own names and numbers will be different.

7Send to document and download the report

  1. Choose the stage (Pre-treatment, Mid-treatment, Post-treatment or Retention) and add notes if you want.
  2. Click Send to document. The traced X-ray and all values are added to the patient document (PDF and Word).
  3. Changed something later? Click Update in patient document. Click Remove to take it out again.
  4. Open In the report to choose what is printed: tick the analyses you want (or click only next to one, for example Downs), and switch Key values and Problem list, diagnosis & plan on or off. The traced X-ray is always printed.
  5. Click Download PDF report for a separate report with the picture and the chosen tables. The same choice is used in the patient document.
  6. Back on the tracing list, Download patient record (PDF) gives every tracing of the patient that was sent to the document, in one file.
  7. In college mode, choose Pre, Mid or Post and click Fill ortho case sheet to write the Downs, Steiner and Tweed values into the orthodontic long case sheet.

Tip: Everything saves by itself while you work. "Saved" in the top right confirms it.

Drawing of the screen. Your own names and numbers will be different.

8PA ceph — Grummons' frontal asymmetry analysis

  1. Before uploading, switch X-ray type from Lateral ceph to PA ceph (frontal), then click Upload X-ray (or From Imaging).
  2. Place the 19 points in order: the midline points Cg (crista galli), ANS, A1 and B1 (upper and lower incisor edges) and Me, then each pair right and left: Z (zygomaticofrontal suture), ZA (zygomatic arch), NC (nasal cavity), J (jugale), U6 (upper first molar), Co (condylion) and Ag (antegonion).
  3. Right and left are the patient's sides: check the R / L marker on the film before placing the paired points.
  4. Calibrate with the ruler for mm values and areas. Angles and the vertical ratios work without calibration.
  5. The mid-sagittal reference (MSR) is drawn from crista galli through ANS. If ANS is off the midline, choose Through crista galli, perpendicular to the Z plane under Summary & diagnosis.
  6. Open All measurements: Horizontal planes (Z, ZA, J, occlusal and Ag planes against the Z plane), Mandibular morphology (Co–Ag, Ag–Me, Co–Me and the angle Co–Ag–Me of each side), Volumetric comparison (area of each half of the mandible), Maxillomandibular comparison, Linear asymmetry (Z, ZA, Co, NC, J and Ag to the MSR, menton and the dental midlines), Maxillomandibular relation (U6 to the J vertical) and Frontal vertical proportions (Cg–ANS / Cg–Me and the other ratios).
  7. Paired values show Right, Left and the Difference with the larger side (R>L or L>R). Summary & diagnosis lists the differences, largest first, for example "Menton 3.0 mm to the patient's left of the MSR".
  8. Send to document and Download PDF report work the same way as for a lateral ceph.

Note: Grummons' analysis has no population norms: it compares the two sides of the same patient. On a PA film, structures at different depths are magnified differently, so compare right with left and one X-ray with the next rather than with fixed numbers.

Drawing of the screen. Your own names and numbers will be different.

9Ricketts superimposition (pre, mid and post treatment)

  1. Trace each X-ray of the patient separately (pre-treatment, mid-treatment, post-treatment and, if you have one, retention), set the right Stage on each, and calibrate each one with the ruler.
  2. Trace at least two lateral cephalograms of the patient (for example pre- and post-treatment), each with its stage set. The Superimposition (Ricketts) card is always on the Ceph Tracing page once a patient is chosen; with only one tracing it says so and offers Upload second lateral ceph.
  3. Click Superimpose (Ricketts) on that card — or inside an open tracing, below Download PDF report.
  4. Check the tracing chosen for each stage. The colours follow the ABO code: pre-treatment black, mid-treatment blue, post-treatment red, retention green.
  5. Open the areas one by one: 1. Ba-N at CC (chin and facial axis), 2. Ba-N at N (point A, angle Ba-N-A), 3. Xi-Pm at Pm (corpus axis: lower incisor, lower molar and condyle), 4. PP at ANS (palatal plane: upper molar and incisor), 5. Composite 1–4 (areas 1 to 4 joined together in one drawing, with all their measurements and inference) and 6. E-plane at OP (lips to the esthetic plane, registered where it crosses the occlusal plane). The teeth are drawn as whole teeth: the incisors from tip to apex, the first molars with crown and roots.
  6. Each area shows the tracings laid over each other on that area's reference line and registration point, a table with the value at every stage and the change, and how far each point moved (forward / back and up / down, in mm).
  7. Write your interpretation for each area, for example "Angle Ba-N-A shows a deviation of 2° after treatment". It is saved with the pre-treatment tracing.
  8. Click Download PDF for the superimposition report: one section per area with the coloured overlay, the table, the changes and your interpretation.

Note: Points needed: Ba, N, Pt, Gn (area 1); Ba, N, A (area 2); Po, Or, the ramus points R1–R4 and Pm (area 3, for Xi); ANS, PNS (area 4); Prn, Pog', the molars and the premolar contact (area 5). Movements in mm need every chosen tracing calibrated; without that only the angles are given.

Drawing of the screen. Your own names and numbers will be different.

Did this not solve it? Message our support team and we will help you.