Study Model Analysis by DentalOnePlus

Study model analysis, straight from your intraoral scan.

Upload the STL from any intraoral scanner, see the upper and lower models on a proper base, click the contact points for every mesiodistal width and get Arch perimeter, Carey, Ashley Howe, Pont, Bolton, Moyers, Tanaka & Johnston, Huckaba and Nance in one screen. Then send it to the patient record or download a PDF report.

No card needed for the trial 9 analyses in one screen Own login for your team
Study Model AnalysisTooth widthsArchResults
Results 24 / 24 teeth
Bolton overall91.56 %
Bolton anterior78.06 %
Upper ALD−1.7 mm
Carey (lower)−2.9 mm
Pont molar expansion+1.9 mm
Send to document
Download PDF report
How it works

From scan to report in four steps

1

Upload the scan

Choose or add the patient and drop in the STL files or the scanner ZIP.

2

Measure the teeth

Click the two contact points of each tooth, 6 to 6, upper and lower.

3

Arch measurements

Arch perimeter, Pont widths and the other measurements, one click each.

4

Report & record

Read every analysis at once, then send it to the patient record or download the PDF.

Analyses

Permanent and mixed dentition, calculated together

Each result shows its formula and the guideline that goes with it. Missing teeth are named, so you always know why a value is empty.

Permanent dentition

Arch perimeter

Space available (segmental arch perimeter) − space required (Σ widths mesial to the first molars), graded as spacing, mild, moderate or severe crowding.

Lundström segments

The arch in six straight segments of two teeth: space available − required for each segment and in total.

Little’s irregularity index

Sum of the five lower anterior contact-point displacements, graded from perfect alignment to very severe crowding.

Peck & Peck

MD ÷ FL index of the lower incisors against 88–92 % (centrals) and 90–95 % (laterals), with the reproximation needed.

Carey’s analysis

Mandibular arch length discrepancy with the suggested plan: stripping, second premolar or first premolar extraction.

Ashley Howe

TTM, PMD and PMD %, PMBAW and PMBAW %, BAL and BAL %, PMBAW against PMD — whether the arch can be expanded or extraction is indicated.

Pont, Linder Harth & Korkhaus

Calculated premolar and molar widths from the upper incisors, compared with the measured widths — how much expansion.

Bolton

Overall (12 teeth) and anterior (6 teeth) ratios against 91.3 % and 77.2 %, with the tooth-size excess in mm.

Mixed dentition

Teeth present

You mark each position permanent, primary or missing; erupted permanent canines and premolars are used as measured.

Moyers

Predicted canine and premolar widths from the lower incisors, 75 % probability level.

Tanaka & Johnston

½ Σ lower incisors + 11.0 mm (upper) or + 10.5 mm (lower), per side.

Huckaba

Actual widths of unerupted teeth from the periapical X-ray, corrected for magnification.

Nance

Arch length against erupted and unerupted teeth, compared with the leeway space.

Everything included

Your digital Vernier caliper

Any intraoral scanner

Upload the STL files or the ZIP from your scanner. Upper, lower and bite are sorted out by themselves.

Proper study models

Each arch is set on a trimmed base and the pair is joined in Bite View, like a plaster model.

Click to measure

Click two contact points for a mesiodistal width; the next tooth starts by itself, 16 to 26. Undo, eraser and drawing on the model.

Arch measurements

Arch perimeter by the segmental method, Pont widths, Korkhaus, Howe — each step explained.

Caliper values too

Type any width you measured on a plaster cast, or copy the other side for a rotated tooth.

9 analyses at once

Permanent and mixed dentition analyses worked out the moment a value changes.

Overjet & more

Any extra measurement, even between the upper and lower arch in Bite View.

PDF report

Your logo, a picture of the model, the width chart and every analysis with its interpretation.

Patient record

Keep each analysis on the patient as pre, mid or post treatment, and download them together.

Staff logins

The owner plus two staff logins, each seeing only this tool.

Any computer

Runs in the browser on Windows or Mac. Nothing to install.

Your data stays yours

Scans are kept per clinic, backed up daily and never shared.

You stay in control

Every point is placed by you

Nothing is guessed. Each width comes from the two points you click on the model, shown on the scan so you can check it, and any tooth can be measured again.

  • Measured points stay visible on the 3D model
  • Typed caliper values and scan values side by side
  • Warning if a scan file is not in millimetres
  • Results are guidelines from the textbook analyses, not a diagnosis
  • Everything saves automatically while you work

Pre, mid and post treatment

Label each analysis by stage. All analyses of a patient stay together, and the ones you send to the record come out as one PDF — ready to compare before and after.

Pre-treatmentMid-treatmentPost-treatment
Pricing

Every plan has everything included.

All features

Study Model Analysis

For orthodontists, clinics and PG students
₹7,999/ year
≈ ₹667 a month
  • Unlimited patients, scans and analyses
  • 3D viewer with study-model bases and Bite View
  • Tooth widths by clicking the scan, or caliper values
  • Permanent dentition: Arch perimeter, Carey, Howe, Pont, Bolton
  • Mixed dentition: Moyers, Tanaka & Johnston, Huckaba, Nance
  • PDF report with your clinic logo
  • Patient record with every analysis
  • All updates included
  • 1 login (the owner), each on one device
Start 14-day free trial

No card needed · already a customer? Log in

Need the complete clinic software?

3D scans with study model analysis are part of the Advanced and college plans — together with appointments, case sheets, billing, WhatsApp, RVG X-rays and Ceph Tracing.

Compare clinic plans

Price per year. Already on the Advanced or a college plan? 3D scans with study model analysis are included — no extra cost.

Questions

Good to know

STL files from any intraoral or desktop scanner, or the ZIP your scanner exports. Scanner files are in millimetres, which is what the measurements need; if a file clearly is not, the software warns you.

A width is the straight-line distance between the two points you click on the scanned surface — as exact as the points you choose, like a caliper. You can zoom in as far as you like, re-measure any tooth, or type a caliper value instead.

No — you click the contact points, guided tooth by tooth. That keeps every number under your control and checkable on the model.

The standard textbook analyses: Arch perimeter, Lundström segments, Carey, Ashley Howe, Pont and Linder Harth (with Korkhaus), Bolton, Moyers (75 % level), Tanaka & Johnston, Huckaba and Nance. Cut-offs vary slightly between authors, and the result is a guide for the clinician, not a diagnosis.

Yes. Upgrade from Plan & billing any time — the unused days are credited and your patients, scans and analyses stay where they are. 3D scans with study model analysis are included in the Advanced and college plans.

The trial lasts 14 days and needs no card. If you do not buy, your scans and analyses stay safe and readable; adding new ones needs a plan.

Analyse your next case on the scan

Start the free trial, upload an intraoral scan and see every analysis for yourself.