CBCT by DentalOnePlus

CBCT reading and reporting, right in your browser.

Open a CBCT from its DICOM folder or a ZIP — axial, coronal and sagittal views, a panoramic along the arch and numbered cross-sections 0.5 to 3 mm apart. Measure the height and width of every implant site in true millimetres, trace the canal, place a virtual implant with safety clearances, and print a report laid out like a radiology centre’s — with the findings each department asks for.

No card needed for the trial Nothing to install True millimetres from the DICOM
Panoramic & cross-sectionsMPR3DReportPDF reportAxial40RLPanoramic510152025303540455055Cross-section 40LBH 14.6 mm7.4 mm8.6 mmØ 4.2 × 11.5 mm3839404142LEFT MANDIBLEToothSliceHeightCrest3 mm belowDensity364014.67.48.6D2Suggested: up to Ø 4.2 × 11.5 mm — 1.5 mm bone each side,2 mm from the inferior alveolar canal
Illustration — example values
How it works

From DICOM to report in four steps

1

Open the scan

Choose the patient and open the DICOM folder or ZIP. The volume is built in your browser and saved to the patient.

2

Draw the arch

Click along the ridge on an axial slice. The panoramic and numbered cross-sections appear at once.

3

Measure slice by slice

On the cross-section through each site, click the crest, the canal or sinus floor and the bone edges.

4

Plan & report

Place the implant, check the clearances, add the findings and download the PDF or send it to the patient document.

Implant sites

The site table radiologists already write

Each site is one row: tooth number, slice number, height from the alveolar crest to the vital structure, width at the crest and a few millimetres below, density and comment — grouped by right and left maxilla and mandible, with the largest standard implant that keeps the clearances.

  • Measured on the cross-section, not typed from memory
  • Width below the crest at 1, 2, 3, 4 or 5 mm
  • Rows you measured elsewhere can be added by hand
  • The cross-section picture goes into the report with each site
ToothSliceHeight (mm)Crest (mm)3 mm belowSuggested
Right maxilla
155217.47.48.6Ø 4.2 × 16
Left mandible
364014.67.48.6Ø 4.2 × 11.5
373010.18.29.4Ø 5 × 8

Example values. Suggestions keep 1 mm below the sinus floor, 2 mm above the canal and 1.5 mm of bone on each side.

For every department

One CBCT, every question answered

Turn on the sections the referring department asked for; each prints in the report under its own heading.

Prosthodontics & implantology

  • Crestal width at the crest and 1–5 mm below
  • Crestal height to the canal, sinus or nasal floor
  • Bone quality (Cawood & Howell, Lekholm & Zarb, Misch)
  • Implant simulation and distance to vital structures

Oral & maxillofacial surgery

  • Impacted, unerupted and supernumerary teeth: position, number, angulation (Winter, Pell & Gregory)
  • Relation to the canal or sinus
  • Cyst / tumour size in three planes, extent, cortical plates
  • Graft evaluation, osteomyelitic and osteonecrotic changes

Orthodontics

  • Palatal bone thickness for mini-implants
  • Impacted canine inclination and position
  • Available alveolar bone
  • Root and crown length, mesiodistal width

Oral medicine & radiology

  • Lesion size, locularity, margins and internal structure
  • TMJ joint spaces against published norms
  • Condyle position (Pullinger & Hollender ratio)
  • Condylar morphology: flattening, erosion, osteophyte, ankylosis

Conservative dentistry & endodontics

  • Root canal morphology (Vertucci type), number of roots and canals
  • Missed or accessory canals, vertical root fracture
  • Periapical lesion extent and sinus involvement
  • Resorption, dilaceration, talon cusp, hypercementosis

Periodontics

  • Buccal and lingual bone at the cervical, middle and apical thirds
  • Furcation involvement (Glickman)
  • Dehiscence and fenestration
  • Bone grafts and implant sites
Everything included

A CBCT workstation in a browser tab

Open the DICOM folder

Choose the folder from the scan centre’s CD or USB, or a ZIP of it. Slices are put in order by their position in the scanner, never by file name.

MPR views

Axial, coronal and sagittal with a shared cross-hair, window presets, zoom and pan. Scroll through every slice.

Panoramic along the arch

Click along the ridge on the axial; the panoramic and the numbered cross-sections follow the curve.

Sites slice by slice

One click measures the crest, the height to the canal or sinus floor and the widths at the crest and below on the cross-section — or place the six points by hand. Saved with the tooth and slice number.

Canal tracing

Click once in the inferior alveolar canal and it is followed along the arch; or mark its upper border by hand. Every implant shows its distance to it.

Automatic measurements, department-wise

Click a tooth: mesio-distal and bucco-lingual widths, crown, root and canal lengths, roots, inclination, bone around the root, apex to sinus floor. Click a lesion: its size in three directions and volume. Click the palate: its thickness. Each result is drawn on the images to check.

Virtual implants, mapped to implant systems

Plan in the sizes of Straumann BLT, NobelParallel CC, NobelActive, Osstem TSIII, Dentium SuperLine, MIS C1 or Adin Touareg (from their catalogues), or any custom size; tilt buccal or lingual, with 2 mm / 1.5 mm / 3 mm clearance checks in red and green.

Implant toolbar like dedicated implant software

Insert implant, implant library with your own implants, implant manager, bone density in HU around and inside each implant (Misch class as a guide), verification views through the implant axis, bucco-lingual and mesio-distal tilt, undo.

Screenshots, PDF and JPEG

Save any view or the whole screen as JPEG or PDF, add it to the report, and download the report as PDF or JPEG pages. The footnote and declaration of your report template are saved for every report.

Sharper images, any view full screen

Views are drawn at twice the scan’s pixels with cubic interpolation and optional sharpening (measurements always use the scan as it is). Enlarge any slice to the whole window or full screen.

3D view

Bone surface or maximum-intensity projection, rotated with the mouse, with a front cut to look inside.

Measure anything

Distance, angle and grey value on any image — every point maps back to true millimetres in the volume.

Report like a radiology centre

Sites grouped by right / left maxilla and mandible, bone quality, department findings, impression in capitals, signature and notes.

Pictures in the report

One click adds any view; each measured site adds its cross-section with the lines and numbers on it.

Patient document

Send the report to the patient’s document with your other records, or download the PDF.

Staff logins

Up to four logins, each seeing only this tool, each on one device.

Honest numbers

Every fixed number has a source

Nothing in the report is invented. Where the literature gives a value it is cited; where CBCT cannot give a number honestly, the software does not pretend to.

Implant clearances

2 mm from the inferior alveolar canal and mental foramen, 1.5 mm from adjacent teeth, 3 mm between implants, 1.5 mm of buccal and lingual bone — all editable.

Bone density

Misch D1–D5 with the Hounsfield ranges Misch gives for medical CT. CBCT grey values are not calibrated Hounsfield units (Pauwels et al., 2015), so the class is the clinician’s choice and grey values are shown for comparison only.

TMJ joint spaces

Anterior 1.3 ± 0.2, superior 2.5 ± 0.5, posterior 2.1 ± 0.3 mm — Ikeda & Kawamura, AJODO 2009 — with the Pullinger & Hollender ratio for condyle position.

Classifications

Cawood & Howell, Lekholm & Zarb, Vertucci, Glickman, Winter and Pell & Gregory — chosen by you and printed as chosen. The software never makes the diagnosis.

Files & storage

Open it here, reopen it anywhere

The scan is read in your browser — the original DICOM never leaves your computer as it is. The volume is compressed and kept with the patient, so the study, its measurements and the report open again from any computer you log in from.

  • DICOM folder, single multi-frame file or ZIP
  • Uncompressed, RLE, JPEG lossless and baseline JPEG
  • Slices ordered by scanner position; uneven spacing is flagged
  • Warns if the scan’s patient name differs from the patient chosen

Pre-operative and follow-up

Label each study by stage. Every report you send to the patient document comes out with the rest of the patient’s records in one PDF.

Pre-treatmentMid-treatmentPost-treatment / follow-up
Kept per clinic, never shared. Windows or Mac.
Pricing

Every plan has everything included.

All features

CBCT

For implantologists, radiologists, colleges and clinics
₹9,999/ year
≈ ₹833 a month
  • Unlimited patients and CBCT studies
  • Axial, coronal, sagittal, panoramic and 3D views
  • Numbered cross-sections with true mm measurements
  • Implant site tables: height, widths, density, slice no.
  • Virtual implant with 2 mm / 1.5 mm clearance checks
  • Findings for implant, OS, ortho, endo, perio and TMJ
  • PDF report with your logo and the images
  • All updates included
  • 1 login (the owner), each on one device
Start 14-day free trial

No card needed · already a customer? Log in

Need the complete clinic software?

CBCT is part of the Advanced and college plans — together with Ceph Tracing, study model analysis, the digital model base, appointments, case sheets, billing, WhatsApp and RVG X-rays.

Compare clinic plans See all single tools

Price per year. Already on the Advanced or a college plan? CBCT is included — no extra cost.

Questions

Good to know

DICOM from the scanner or scan centre — a folder of slices, one multi-frame file, or a ZIP of either. Uncompressed, RLE, JPEG lossless and baseline JPEG are read. If a study is saved as JPEG 2000 or JPEG-LS, export it again from the scanner software as uncompressed DICOM; the viewer tells you when that is needed.

Every measurement is made in millimetres from the voxel size stored in the DICOM, and every point you click maps back to its exact place in the volume, so a distance on a cross-section is the true 3D distance. Accuracy is still limited by the scan itself (voxel size, movement, artefacts), so dimensions are indicative and the report says so.

Edges are put half-way between the grey values on either side, to a fraction of a voxel, so the scanner’s grey scale does not matter. The automatic tools are checked on synthetic test scans with a known answer (computer-made phantoms, not patient scans): there, crest, widths and the vertical height to the canal come within 0.5 mm, and the traced canal within 0.5 mm of its true course. Validation on real patient scans marked by radiologists is still in progress, so treat every automatic value as a suggestion: each one shows a confidence, low-confidence results are not drawn at all, and nothing enters the report until you check and save it. You can always measure by hand.

No. CBCT grey values are not calibrated Hounsfield units and vary between machines, so the software does not turn them into a density class. You choose the Misch class; grey values are shown only to compare areas within the same scan.

No. It gives the views and the measurements; the radiologist or clinician chooses every classification and writes the impression. The report carries the standard notes that CBCT is an adjunct to the clinical examination.

The DICOM is read in your browser and the volume is uploaded once, compressed, to your clinic’s own storage, so it opens again on any computer you log in from. Each clinic has 25 GB for CBCT; delete old studies you no longer need, or ask us for more.

A current Chrome, Edge, Safari or Firefox on Windows or Mac. A computer with 8 GB of memory handles a typical dental CBCT; very large full-face scans need more. The 3D view needs WebGL 2, which almost every computer from the last few years has.

Yes. Upgrade from Plan & billing any time — the unused days are credited and your patients and CBCT studies stay where they are. CBCT is included in the Advanced and college plans.

The trial lasts 14 days and needs no card. If you do not buy, your reports stay safe and readable; adding new studies needs a plan.

Report your next CBCT in minutes

Start the free trial, open a CBCT folder and measure your first implant site slice by slice.